Separate the room uses
Ask the designer to identify each room on the fixture schedule. For a Canadian project with a private suite and a public lobby, give the suite basin and the lobby basin separate rows even if the finish sample is shared. Record the buyer’s state or province and the city where the fixtures will be installed.
Check the destination and the test condition
For covered models made on or after July 1, 2026, the Canadian federal table sets these maximums at 414 kPa (60 psi). Keep the value in its published unit when requesting evidence.
| Use | Maximum at the test pressure | Detail to record |
|---|---|---|
| Private lavatory | 4.7 L/min | Identify private-use model and replacement aerator. |
| Public lavatory, non-metering | 2.0 L/min | Identify the public-use configuration. |
| Kitchen | 7.0 L/min | Record optional temporary flow separately, up to 8.5 L/min. |
| Metering | 0.95 L per cycle | Use volume per cycle on a separate row. |
The US federal table lists 2.2 US gpm for lavatory and kitchen faucets and 0.25 US gallons per cycle for metering faucets. Check the destination state and local specification with the designer before choosing the US variant. A federal maximum alone does not settle the purchase specification.
Canadian manufacturing-date rule · Canadian product classes, test method and limits · US federal faucet table.
Match each order line to a test record
| Line | What the buyer records |
|---|---|
| Destination and room | City, state or province, fixture tag and use. |
| Product as supplied | Base model, flow-variant suffix, finish, aerator and spare-part code. |
| Performance | Agreed rate and unit, test pressure, or volume per cycle for a metering faucet. |
| Evidence | Exact-model test document, revision, listing if applicable and carton marking. |
| Decision | Approved sample, quantity and person responsible for substitutions. |
A supplier may offer one assembly for two destinations. Match the part code, test documents and carton marking for both rows before combining quantities. If the part or documentation differs, keep separate stock codes and list the matching spare on each carton schedule.
Give the supplier wording it can confirm
Supply [model and variant] for [destination, fixture tag and use]. Confirm the rated flow, unit, test pressure and aerator part number. Attach the supporting document for this configuration and the proposed carton label. List each substitution as a separate item for approval before packing.