Which Configuration Fits?
Select a pedestal, column, sculpted, twin or project basin according to room width, rough-in position and required height.

Factory-backed sourcing · Foshan, China
Pedestal and freestanding basins for importers, distributors, developers, hospitality teams, contractors, showroom buyers and project specifiers. Confirm overall height, bowl width and depth, column footprint, drain outlet type and position, water rough-in height, tap arrangement, floor condition, fixing method, overflow status where confirmed and finish reference against an approved drawing, sample, technical sheet or confirmed model.
Pedestal & Freestanding Basins are one-piece floor-standing wash basins for bathrooms where no vanity cabinet is used. WNS Global supports practical B2B requirements review, document alignment and export communication from Foshan, China. Final values remain subject to approved specification. This line is produced at our own base in Foshan, so a buyer deals with the sanitary ware manufacturer directly rather than through an intermediary.
Configuration range
Select basin height, bowl size and footprint first, then confirm floor drain position, water rough-in, tap arrangement and surface reference.

A one-piece bowl and column standing on the finished floor with the trap concealed inside.
Explore Bathroom Vanities →
A slimmer floor-standing profile for narrow guest bathrooms and cloakrooms.
Explore Bathroom Vanities →
A shaped floor basin specified as the visual centerpiece of the room.
Explore Bathroom Vanities →
Two matched floor basins planned around spacing, mirror centers and tap positions.
Explore Bathroom Vanities →
Repeatable floor-basin packages for room-type specifications.
Explore Bathroom Vanities →Specification control
Final values should be controlled by a project drawing, approved sample, technical sheet or confirmed model. Where a value is not agreed, record it as “Available / confirm per model.”
What buyers should confirm: overall height, bowl width and depth; column footprint; drain outlet type and position; water rough-in height; tap arrangement; overflow status if confirmed; fixing method; clearance to walls; surface or finish reference; and documents to confirm.

| Overall height and bowl size | Available / confirm per model | Column footprint and clearance | Confirm against approved drawing |
|---|---|---|---|
| Drain outlet type and position | Confirm per selected configuration | Tap arrangement and clearance | Confirm with plumbing plan |
| Floor condition and fixing method | Confirm with responsible trade | Overflow status if confirmed | Confirm per selected configuration |
| Surface or finish reference | Confirm with approved reference | Project documents to confirm | Drawing, sample, technical sheet and quotation |
| Packing and labels | Confirm order-specific protection, labels and document needs before order approval | ||

Buyer decisions
Review the complete basin-and-cabinet package, not just the visible surface.
Select a pedestal, column, sculpted, twin or project basin according to room width, rough-in position and required height.
Provide finished floor level, room width, drain outlet type and position, water centerlines, required basin height, tap reference and installation responsibility.
Confirm surface reference, bowl size, drain outlet, tap arrangement, overflow status and supplied component scope.
Show overall height, bowl and column dimensions, drain outlet position, water rough-in, tap arrangement, fixing method, surface reference and responsible approver.
The buyer or project team should verify destination-market requirements for structure, water connection, drainage and installation.
Risk control
WNS Global can support requirements, drawing or sample review, packing alignment and issue escalation. The buyer remains responsible for local structure, services, installation suitability and site access.

| Risk to control | Pre-order sourcing response |
|---|---|
| Drain outlet and water rough-in | Confirm drain outlet type, water rough-in height and finished floor level before drawing approval. |
| Tap reach and unit spacing | Review tap reach, bowl height and spacing between units with the responsible trade. |
| Floor flatness and fixing method | Confirm floor flatness, load path and fixing method before approval. |
| Room width and clearances | Confirm room width and clearance to walls and adjacent fixtures with the project team. |
| Approved drawing revision | Lock the approved drawing revision before order confirmation. |
| Handling of a one-piece floor unit | Align protective packing, handling and the installation sequence for a one-piece floor unit. |

Private-label and projects
WNS Global can review height, bowl size, column profile, drain outlet, tap arrangement, surface direction and packaging, subject to technical and commercial feasibility, an approved reference and order confirmation.
Room drawings, dimensions, required height, drain outlet and water positions, floor condition, finish reference, quantity, target market and packing request.
Feasibility, configuration fit, reference clarity and order-document alignment.
Project sequence
Use one approved record for dimensions, drain outlet, water rough-in, tap arrangement, surface reference and order scope.

Share room drawings, required height, bowl size, drain outlet and water positions, floor condition, finish reference and quantity.
Review dimensions, drain outlet, water rough-in, tap arrangement, floor condition, plumbing and surface reference.
Approve the applicable drawing, technical sheet, sample, finish reference or component schedule.
Confirm approved order details, packing and the agreed inspection scope.
Align labels, packing list, agreed documents and shipment coordination.
Order-specific inspection
Inspection scope and acceptance criteria are agreed for the order. The final review compares the selected product with the approved specification, finish reference and packing requirement.
Any special test, certificate or local standard remains subject to the selected product and destination-project requirement.

Project fit
Choose the application only after room width, rough-in position, required height and floor condition are defined.

Repeat one floor basin across room types with a fixed rough-in.
Discuss project requirements →
Use a slim floor basin where cabinet storage is not required.
Discuss project requirements →
Specify floor basins where service points and spacing are controlled.
Discuss commercial requirements →
Replace a vanity with a floor basin after confirming drain and water rough-in.
Discuss retail requirements →
Product definition
Pedestal & Freestanding Basins combine bowl and column as one floor-standing piece that carries its own load and conceals the trap inside the column. They can be a full pedestal, a slimmer column, a sculpted feature form or a matched pair. The product is selected to coordinate with finished floor level, drain outlet type and position, water rough-in height, tap arrangement, clearance to walls, fixing method, surface reference and installation sequence. A drawing, approved sample, technical sheet or confirmed model should define final scope. Do not assume a tap, waste, trap, mirror, cabinet, wall preparation, installation or visible accessory is included unless the written quotation names it.
A styled image does not define supply scope. Confirm taps, wastes, traps, mirrors, plumbing components, installation and visible accessories in the written quotation.
Not the same as

Decision guide
Compare pedestal, column and sculpted routes by installation, planning variables and drawing verification.
| Approach | Installation or integration | Typical project fit | Buyer confirmation point |
|---|---|---|---|
| Freestanding pedestal basin | One-piece bowl and column on the finished floor, trap concealed inside the column. | Hotel guest bathrooms, powder rooms and feature bathrooms. | Drain outlet type, water rough-in height, finished floor level and tap type. |
| Column basin | Slimmer column footprint for narrow rooms, with the same concealed-trap principle. | Cloakrooms, compact guest bathrooms and tight plan widths. | Overall height, footprint, clearance to walls and tap reach. |
| Sculpted or twin layout | Shaped or paired floor basins coordinated with spacing, mirror centers and lighting. | Feature bathrooms, suites and showroom displays. | Spacing between units, mirror and tap centerlines, surface reference and supplied scope. |
RFQ checklist
Attach these points to the enquiry before quotation or purchase-order approval.


Factory-backed coordination As a Foshan sanitary ware supplier we can also bring in the fittings that sit around it, so one contact covers the whole bathroom.
WNS Global is a factory-backed bathroom supplier and export team from Foshan, China. For pedestal & freestanding basin projects, the role is to coordinate a clear buying brief, selected configuration, export communication and project-document alignment against the approved reference.
Share room drawings, dimensions, required height, drain outlet and water positions, floor condition, finish reference, quantity and target market.
Review dimensions, column profile, drain outlet, tap arrangement, floor condition, finish reference and supplied scope.
Keep product, packing, labels, documents and approval ownership aligned.
Coordinate agreed inspection, packing and shipment-document questions.
Exact product availability, materials, finishes, commercial terms and delivery details remain subject to written confirmation for the selected order.
About WNS Global
Buyer questions
Model-dependent points should be confirmed through the selected product reference and approved project documents.
Start with overall height, bowl size, column footprint, drain outlet, water rough-in, tap arrangement, floor condition and surface reference. Confirm the Pedestal & Freestanding Basins configuration on the approved drawing.
Share room drawings, dimensions, required height, drain outlet and water positions, floor condition, finish reference, quantity and the latest revision.
Do not assume they are included. Confirm the exact supplied component scope and the responsible installation party in the approved quotation.
WNS Global can review height, bowl size, column profile, drain outlet, tap arrangement, surface direction, packaging and drawing approval subject to feasibility, an approved reference and order confirmation.
Inspection follows the agreed order scope, including height, bowl and drain-outlet positions, surface and edge condition, approved revision, components, labels, packing and the technical reference.
The buyer or responsible project team should verify destination-project requirements for structure, water connection, drainage and installation.
Learn before you buy
A bowl on the counter, and the three things it changes.
Where the bowl meets the top decides cleaning, height and cost.
Draw the empty space first. The clearances are what fill the room.
Approach, transfer and reach decide the plan before any fixture.
Mounting, valve, flow and finish, in the order a spec is read.

Project enquiry Sanitary ware wholesale orders and single project schedules are handled by the same team.
Use Your Request to share your quantity estimate, drawing, reference photo, required finish, target market or required date where relevant. WhatsApp is the faster contact route for a first discussion.