What Is a Walk-In Screen?
A fixed glass panel system that defines an open-entry shower area.

Open-entry shower planning · Foshan, China
Fixed-panel sourcing built around the complete wet zone
Walk-in shower screens use fixed glass panels to define an open-entry shower zone. WNS Global supports drawing-based sourcing where screen coverage, return panels, drainage, floor finish, wall conditions and room layout are confirmed for each project. This line is produced at our own base in Foshan, so a buyer deals with the sanitary ware manufacturer directly rather than through an intermediary.
Configuration range
Select the panel system first. Then confirm screen coverage, open entry, support, wall fixing, drain relationship and floor condition on the approved drawing.

Minimal visible framing keeps the wet zone open while panel dimensions, support direction, wall fixing, floor joint and splash coverage require approval.
Discuss this configuration →
Profile-supported screens coordinate visible framing, wall adjustment, panel alignment, support hardware, floor or tray condition and the specified finish direction.
Discuss this configuration →
One fixed panel creates a direct open entry when screen width, spray direction, user path, drainage and nearby fixtures are reviewed together.
Discuss this configuration →
A return panel increases side coverage where its width, angle, support, cleaning access and relationship with the entry are confirmed.
Discuss this configuration →
Wet-room projects require coordinated floor falls, drainage, waterproofing responsibility, accessible route, screen mounting and target-market requirements before purchase.
Discuss this configuration →
Drawing-based screens coordinate non-standard panels, return sections, supports, profiles, finishes, installation conditions, labels and export project packing requirements.
Send project brief →Specification control
Record every field on the approved product drawing. Unverified values require project confirmation.
Site measurements, floor falls, drainage and fixing responsibility must be confirmed before purchase.

| Screen width | Confirm by approved product drawing | Height | Confirm by approved product drawing |
|---|---|---|---|
| Fixed-panel count | Confirm by approved product drawing | Return-panel option | Confirm by approved product drawing |
| Glass specification | Confirm by approved product drawing | Support bar | Confirm by approved product drawing |
| Wall profile | Confirm by approved product drawing | Floor or tray condition | Confirm before purchase |
| Drainage direction | Confirm with room plan | Hardware finish | Confirm against approved reference |
| Mounting type | Confirm by approved product drawing | Packaging | Confirm by approved order |

Buyer decisions
Review the complete wet area, not only the glass panel.
A fixed glass panel system that defines an open-entry shower area.
Width depends on shower position, spray direction, room depth, entry and drainage.
Use project review to decide whether extra side coverage supports splash control.
Floor slope and drain position direct water away from the open entry.
Support depends on panel geometry, mounting, walls and the approved system.
Provide floor, drainage, waterproofing scope, access needs and local requirements.
Risk control
WNS Global organizes drawing, measurement and component checks before production. Installation, waterproofing, drainage and local compliance remain project-specific.

| Risk | WNS Global sourcing response |
|---|---|
| Insufficient screen coverage | Request shower and room positions before confirming panel dimensions. |
| Unsuitable drainage | Review drain location and floor direction with the project team. |
| Wall-condition mismatch | Request finished wall details, photos and fixing-zone confirmation. |
| Inadequate support | Approve the support direction and hardware set on the drawing. |
| Water escape | Review open entry, spray direction, return panel and floor falls. |
| Incorrect hardware | Approve profiles, supports, fittings, finish references and quantities. |
| Bad site measurement | Record finished dimensions at several points and identify the approver. |
| Glass handling damage | Agree edge protection, package labels, unloading and site handling. |

Private-label and projects
Technical review is required before quotation. Configurable directions depend on the selected screen system and approved project specification.
Project sequence
Seven steps align screen coverage, drainage, support and shipment scope.

Share layouts, photos, quantities and project references.
Record drain location, floor fall and mounting condition.
Define the main screen and any return section.
Identify profiles, bars, fittings and visible references.
Check panels, entry, drainage relationship and fixing.
Confirm labels, documents, quality scope and packaging.
Inspect, pack and align documentation and handling scope.
Pre-shipment review
Inspection compares the component set with the approved drawing, order and agreed quality reference.
Inspection scope should be agreed in the purchase order or approved quality standard.

Project fit
Open-entry screens suit projects that coordinate glass coverage with drainage, access and the complete room plan.

Fixed screens coordinated with floor falls, drainage, waterproofing scope and open entry.

Room schedules aligned through approved panels, supports, finishes and packing references.

Open shower layouts reviewed around fixtures, circulation, floor and visible hardware.

Repeat room types coordinated with finished dimensions, drainage and installer information.

Open-entry direction considered subject to local accessibility and project requirements.

Panel proportions, return sections and finishes aligned with the room specification.

Product definition
A walk-in shower screen is generally a fixed glass panel system that forms an open shower entry without a full door enclosure.
Some layouts include a return panel for additional side coverage. The return may be fixed or another technically approved configuration.
A walk-in screen is not a guarantee of water containment. Drainage, floor slope, shower direction, panel coverage and room planning determine the complete result.

Decision guide
Compare openness, water planning and moving parts against the actual bathroom.
| Option | Openness and entry | Splash and drainage | Moving parts and site needs |
|---|---|---|---|
| Walk-in screens | Direct open entry with fixed-panel coverage | Requires coordinated screen width, floor falls and drainage | Few moving parts; wall and floor fixing still matter |
| Sliding enclosures | Defined entry within overlapping panels | More enclosed boundary with track and seal relationships | Rollers, track access and lateral movement require review |
| Hinged enclosures | Direct opening where swing space is available | Door, seals and threshold form the selected boundary | Wall support, handing and full swing must be confirmed |
| Folding doors | Articulated panels reduce some opening projection | Boundary depends on panels, seals and tray relationship | Multiple hinges and folded position need coordination |
RFQ checklist
Copy these points into the quotation request and identify the drawing approver.


Factory-backed coordination As a Foshan sanitary ware supplier we can also bring in the fittings that sit around it, so one contact covers the whole bathroom.
WNS Global supports factory-backed sourcing communication from Foshan, China.
Share wet-room layouts, drainage information, screen dimensions, drawings, quantities, technical needs and target-market requirements. We coordinate configuration, drawing approval, packing and inspection questions.
Dimensions, materials, compliance, lead time and commercial terms remain subject to written project confirmation.
About WNS Global
Buyer questions
Project-specific answers remain subject to approved drawing and project confirmation.
No fixed screen guarantees full water containment. Splash performance depends on panel coverage, shower position, user direction, drainage, floor slope and the room layout.
A walk-in screen is generally based on a fixed panel. Some projects add a fixed return panel or an approved movable return section.
The open entry relies on controlled floor falls and a suitable drain position. Drainage design and local waterproofing responsibility must be confirmed before purchase.
Consider a return panel when room depth, spray direction or nearby fixtures require more side coverage. Confirm its size, angle and support on the drawing.
They can form part of a wet-room plan, but floor construction, drainage, waterproofing, access and local requirements remain project-specific.
Support depends on panel dimensions, mounting system, wall conditions and the approved configuration. Do not remove or reposition support without technical review.
Minimum order quantity depends on the approved configuration, dimensions, finish, packaging, labeling and order mix. Share the required quantity for commercial confirmation.
Yes, subject to technical and commercial confirmation. Send drawings, finished dimensions, drainage information, quantities, target market, finish and packaging requirements.
Learn before you buy
Contain the water, or waterproof the room. The risk moves with it.
A waterproofing strategy, not a shower without a door.
Approach, transfer and reach decide the plan before any fixture.
One plane or four. Large tiles settle the argument.
Toughened glass has no adjustment. Measure after tiling.

Project enquiry Sanitary ware wholesale orders and single project schedules are handled by the same team.
Send the room plan, screen dimensions, drainage, floor condition, return-panel need, quantity, destination and market requirements.