Do I Need a Three-Way Faucet or a Separate Filter Tap?

Choose by the number of holes you can drill and how the user will draw drinking water. The table compares the two layouts as they appear in the ranges we source.
| Point | Three-way faucet | Separate filter tap |
|---|---|---|
| Holes | One (most models); one model uses three deck pieces | One extra hole beside the main mixer |
| Outlets | Mixed water and filtered water from one spout | Filtered water only |
| Controls | Mixer handle plus a separate filtered-water control | One small lever |
| Catalog examples | 823, 827, 505, 793, 7514 | 538-2, 538-7, 538-5 |
| Main risk | Filtered connection not specified; wrong control used for drinking water | Extra hole needed; hole size must match the shank |
A three-way faucet gives a clean worktop with one fitting. A separate tap is simpler to plumb and easier to replace, and the user cannot draw hot water from the drinking-water outlet by mistake. If the sink or worktop already has one spare hole, a filter tap is often the lower-risk choice.
Is the Filtered Water Really Kept Separate?

It should be, and the drawing usually shows it. In a three-way faucet, filtered water enters through its own inlet and should reach the spout through its own channel, without passing through the mixing cartridge. If it shared a passage with the hot and cold water, the filtered water would be mixed with unfiltered water before it left the spout.
The evidence to look for is on the dimension drawing. The drawing for model 7514, a three-piece layout, labels four separate connections under the deck: hot water, cold water, a filtered-water connection port, and the outlet to the side spray. Models 505 and 793 show two braided hoses marked “2-G1/2” plus a third, thinner tube with its own fitting; that third tube is the filtered line.
What to do: ask the supplier to mark on the drawing which inlet is filtered water, and to confirm in writing that the filtered water flows through a separate channel to its own outlet in the spout. Check it on the sample: with only the filter line pressurized, water should come out only when the filtered-water control is opened.
Which Filter Will It Connect To?

The faucet does not decide the filter, but its filtered-water inlet must fit the filter’s outlet. The catalog pages we work from do not name a filter, a filter brand or a filter type for any of the eight models, so this is the one connection you must define yourself.
The dedicated filter taps give more detail than the combined faucets. The 538-2 drawing shows a deck hole of Ø14–Ø18 mm, a threaded shank marked m12×1, a Ø45 mm base and a Ø9.5 mm spout. The 538-7 drawing shows a Ø15 mm hole with the same m12×1 shank. Below the shank both drawings show a fitting for the supply tube, but its size is not written on the page.
What to do: start from the filter. Note the filter’s outlet fitting (tube size and type), then ask the faucet supplier for the size and type of the filtered-water inlet and whether a matching adapter is included. If the filter will be bought locally in the destination market, send its installation sheet with the inquiry. Feed the filter from the supply the filter maker specifies, which is normally the cold line.
What Connection Sizes Should Be on the Spec Sheet?

Four sizes decide whether the faucet installs without extra parts: deck hole, deck thickness, shank thread and hose threads. The drawings in the water-purification section give most of them:
| Model | Deck hole | Shank thread | Hot and cold hoses | Filtered inlet |
|---|---|---|---|---|
| 823 | Max Ø35 mm | M32×1.5 | 2 × G1/2 | Not dimensioned |
| 827 | Max Ø35 mm; deck max 30 mm | M32×1.5 | 2 × G1/2 | Not dimensioned |
| 505 | Ø35 mm | Not stated | 2 × G1/2, 500 mm | Separate tube, size not stated |
| 793 | Ø35 mm; deck max 30 mm | Not stated | 2 × G1/2, 500 mm | Separate tube, size not stated |
| 538-2 / 538-7 | Ø14–Ø18 mm / Ø15 mm | m12×1 | None (single supply) | Fitting shown, size not stated |
“G1/2” is the ISO 228-1 designation for a parallel pipe thread, a thread on which the seal is made by a washer or gasket, not by the thread itself [S6]. Check that the hose ends match the outlets of the angle valves used in your market; if they do not, add adapters to the order rather than leaving the installer to find them. Also check the worktop: a stone top thicker than the stated maximum deck thickness needs a longer shank or a different model.
How Much Water Will Each Outlet Deliver?

Expect two different flows. The mixed-water side behaves like any kitchen faucet. The filtered side is limited by the filter, the tube and the inlet pressure, so it is normally slower. The catalog pages give an inlet pressure range (0.1 MPa dynamic to 1.0 MPa static) but no flow rate for either outlet.
For the US, federal rules cap kitchen faucets at 2.2 gallons per minute (8.3 L/min) measured at a flowing pressure of 60 psi (414 kPa) [S5]. Some states and local codes set lower limits. That cap is a ceiling for the faucet, not a promise about the filtered outlet.
What to do: ask for the mixed-water flow and the filtered-water flow, each measured at a stated pressure, and check that the mixed-water figure fits the destination market. Take the filtered flow from the filter maker’s data, because the filter, not the faucet, usually sets it. Our guide to aerated and laminar streams explains how the outlet insert changes how the stream looks and splashes.
Which Certificate Covers the Faucet, and Which Covers the Filter?

They are separate, and one does not replace the other. A faucet certificate says the faucet’s materials are safe in contact with drinking water. A filter certificate says what the filter removes. Neither tells you the other.
| Product | Standard (North America) | What it addresses |
|---|---|---|
| Faucet | NSF/ANSI/CAN 61, Section 9 | Contaminants leaching from endpoint devices such as faucets; lower lead limits mandatory from 1 January 2024 [S1] |
| Faucet | Lead-free definition, 40 CFR 143.12 | Not more than a weighted average of 0.25 % lead on wetted surfaces; filter media are excluded from that wetted area [S4]; NSF/ANSI/CAN 61 and 372 certifications are evaluated against this rule [S3] |
| Filter | NSF/ANSI 42 | Aesthetic impurities such as chlorine, taste and odor [S2] |
| Filter | NSF/ANSI 53 | Contaminants with a health effect [S2] |
| Filter | NSF/ANSI 58 / 401 | Reverse osmosis systems / emerging contaminants [S2] |
NSF itself notes that certification does not mean a filter reduces every possible contaminant [S2]. So the filter’s certificate must list the specific reduction claims you plan to make. For the faucet, ask for the certificate listing that names the exact model, and check whether it covers the whole three-way faucet or only a part. Our article on lead-free brass and NSF/ANSI 61 explains the faucet side in more depth, and checking the scope of a lead-free mark shows how to read a listing.
This page does not state that any product WNS Global supplies holds these certifications. Ask for the documents for your market model by model.
How Many Holes Does the Sink or Worktop Need?

Count the holes before choosing the model. Most combined faucets in the range install through one hole of up to Ø35 mm. The exception is 7514, which installs as three deck pieces (spout, side spray and a separate control). A dedicated filter tap needs one extra small hole, Ø14–Ø18 mm on the 538-2 drawing.
On a pre-drilled sink, the hole count is fixed. On a stone worktop, the fabricator needs the hole positions and diameters before cutting. Our guide to specifying cutouts covers how to put hole sizes and positions on the drawing.
What to do: send the sink model or worktop drawing with the inquiry, state the deck thickness, and ask the supplier to confirm hole count, hole diameter and maximum deck thickness for the chosen faucet.
What Should Go Into the Purchase Order?

Copy this into the order or the inquiry and fill in the blanks. Each line closes one of the gaps above.
- Layout: three-way faucet / separate filter tap; model code and finish code.
- Waterways: supplier confirms filtered water has its own channel and outlet and does not pass through the mixing cartridge; inlet marked on the drawing.
- Filtered inlet: size and type of fitting ______; adapter to suit filter model ______ included (yes/no).
- Hot and cold hoses: thread (e.g. G1/2), length ______ mm; adapters for site valves ______.
- Deck: hole Ø ______ mm, maximum deck thickness ______ mm, number of holes ______.
- Flow: mixed ______ L/min and filtered ______ L/min at ______ MPa.
- Faucet documents: certificate or test report for ______ (market rule) naming this model.
- Filter documents: certificate to NSF/ANSI ______ for the claims we will make (supplied by the filter maker).
- Spares: cartridge and outlet insert part numbers; see cartridge service kits and replacement aerators.